bidib-examples-en
Table of Contents
BiDiB Setup Examples
Switch setup
Example Servo
Bus → Decimal Unique-ID
This example shows how to address servo port 1 on a LightControl. The accessory flag must be unchecked.
The decimal Unique-ID is set in the Bus field which can be done with D&D.
Parameter/Value
5698+
Optional the servo position can be specified:
- Parameter → straight position
- Value → thrown position
Example Dual Coil
- Disable "Single Gate"
Address + 1 is used for controlling the second coil of the switch motor. (turnout)
DCC Accessory
Field | Value | Remark |
---|---|---|
Bus | Decimal Unique-ID | Default GBMBoost Master if left empty. If MultiMaus1) accessory commands should also processed the Bus value must be set to the UID of the GBMBoost Master. |
Protocol | NMRA-DCC | |
Address | 1…65536 | Is mapped to NMRA 0…65535 |
Port | Not used | |
Gate | 0, 1 | Only for single coil switch motors or Outputs |
Type | Accessory |
Signal setup
Example MoBaLiSt
Bus → Decimal Unique-ID
This example shows how to address lights port 1…4 on a MoBaLiSt. The accessory flag must be unchecked.
The decimal Unique-ID is set in the Bus field which can be done with D&D.
Sensor setup
Bus → Decimal Unique-ID
Address → Port number + 1
Server trace
MSG_BM_CONFIDENCE: uid=00010068 path=0.0.0.0 void=0 freeze=0 signal=0 sensor bus=00010068 addr=5 state=occ ident=1057 type=loco-addr-fwd
Sensor message | |
---|---|
bus | Unique-ID (hex value) |
addr | local module port address |
state | occupancy: free/occ |
ident | Railcom loco address |
See http://www.bidib.org/protokoll/bidib_occ.html for more information about confidence.
1)
Or any other Xpressnet throttle.
bidib-examples-en.txt · Last modified: 2020/12/03 22:04 by rjversluis