User Tools

Site Tools


bidib-examples-en

BiDiB Setup Examples

Switch setup

Example Servo

Bus → Decimal Unique-ID

This example shows how to address servo port 1 on a LightControl. The accessory flag must be unchecked.
The decimal Unique-ID is set in the Bus field which can be done with D&D.

Parameter/Value

5698+
Optional the servo position can be specified:

  • Parameter → straight position
  • Value → thrown position


Example Dual Coil

  • Disable "Single Gate"

Address + 1 is used for controlling the second coil of the switch motor. (turnout)


DCC Accessory

Field Value Remark
Bus Decimal Unique-ID Default GBMBoost Master if left empty.
If MultiMaus1) accessory commands should also processed the Bus value must be set to the UID of the GBMBoost Master.
Protocol NMRA-DCC
Address 1…65536 Is mapped to NMRA 0…65535
Port Not used
Gate 0, 1 Only for single coil switch motors or Outputs
Type Accessory


Signal setup

Example MoBaLiSt

Bus → Decimal Unique-ID

This example shows how to address lights port 1…4 on a MoBaLiSt. The accessory flag must be unchecked.
The decimal Unique-ID is set in the Bus field which can be done with D&D.


Sensor setup

Bus → Decimal Unique-ID
Address → Port number + 1

Server trace

MSG_BM_CONFIDENCE: uid=00010068 path=0.0.0.0 void=0 freeze=0 signal=0
sensor bus=00010068 addr=5 state=occ ident=1057 type=loco-addr-fwd
Sensor message
bus Unique-ID (hex value)
addr local module port address
state occupancy: free/occ
ident Railcom loco address

See http://www.bidib.org/protokoll/bidib_occ.html for more information about confidence.


1)
Or any other Xpressnet throttle.
bidib-examples-en.txt · Last modified: 2020/12/03 22:04 by rjversluis